Jitter analysis and clock data recovery
R&S
®
RTO6
1084User Manual 1801.6687.02 ─ 05
Before starting the quick start analysis, set the Analyzed source and the Signal T
ype .
The quick start analysis performs the following:
A bit rate estimation is performed on the applied signal.
A software CDR of second order is used as reference signal for the jitter analysis.
Enables basic measurement
"Event Count" and advanced jitter components:
TJ@BER, RJ, TJ, DJ and PJ.
In the "Result" dialog it enables:
"Bathtub" for total jitter @ BER (TJ@BER).
"Step response" for the analyzed source signal.
"Histogram" for RJ, TJ, DJ, DDJ and PJ.
Enables the advance jitter measurement analysis.
Remote command:
ADVJitter<m>:SIGNal:QUICkmeas on page 2486
Reference Level
Opens a dialog to set the reference levels. For details, see Chapter 8.2.4, "Reference
levels", on page 307.
Gating
Opens a dialog to set up the gate of the waveform for the advanced jitter analysis. The
gate limits the measurement to a user-defined range of the waveform.
Use gate ← Gating
Enables the gating setup.
Advanced jitter and noise (option R&S RT
O6- K133/K134)