Loading...
Jitter analysis and clock data recovery
R&S
®
RTO6
1107User Manual 1801.6687.02 ─ 05
Remote command:
ADVJitter<m>:
RESult:
VERTical:HBINs on page 2504
Continuous auto scale ← Settings for histogram and track
If enabled, the measurement scale for track is set automatically. If disabled you can
manually set a Meas scale and Meas offset.
Remote command:
ADVJitter<m>:RESult:VERTical:CONTinuous on page 2504
ADVJitter<m>:RESult:VERTical:BHContinuous on page 2504
ADVJitter<m>:RESult:VERTical:NHContinuous on page 2505
Measurement type ← Settings for histogram and track
Selects the basic measurement type to apply the scale to.
Remote command:
ADVJitter<m>:RESult:VERTical:BMTYpe on page 2504
Meas scale ← Settings for histogram and track
Sets a measurement scale. The unit depends on the measurement type.
Remote command:
ADVJitter<m>:RESult:COMPonents<n>:SCALe on page 2505
Meas offset ← Settings for histogram and track
Sets a measurement offset. The unit depends on the measurement type.
Remote command:
ADVJitter<m>:RESult:COMPonents<n>:OFFSet on page 2506
Settings for spectrum
Defines the settings for the histogram and track diagrams.
Continuous auto scale ← Settings for spectrum
If enabled, the measurement scale for the spectrum is set automatically. If disabled you
can manually set a Meas scale
and Meas offset.
Remote command:
ADVJitter<m>:RESult:VERTical:JSContinuous on page 2505
ADVJitter<m>:RESult:VERTical:NSContinuous on page 2505
Advanced jitter and noise (option R&S RT