Remote control commands
R&S
®
RTO6
1802User Manual 1801.6687.02 ─ 05
*RST: STOF
TRIGger<m>:CAN:FDATa:STANdard <Standard>
Selects the CAN standard. Use ANY if the standard of the signal is unknown.
The setting is available in CAN FD option.
Parameters:
<Standard> ANY | CAN | CANFd
*RST: CAN
TRIGger<m>:CAN:FTYPe <FrameType>
Selects the CAN frame type if
TRIGger<m>:CAN:TYPE is set to FTYP (frame type) or
ID (identifier).
For data and remote frames, the identifier format has to be set with TRIGger<m>:
CAN:ITYPe.
See also: "Frame type" on page 589
Parameters:
<FrameType> ANY | DATA | REMote | ERRor | OVERload
Available values depend on the CAN standard and on the
TRIGger<m>:
CAN:TYPE setting:
Remote frames are not available in the CAN FD protocol.
If the trigger type is set to FTYP (frame type), you can set the
values DATA | REMote | ERRor | OVERload.
If the trigger type is set to ID (identifier), you can set the values
ANY | DATA | REMote.
*RST: ANY
TRIGger<m>:CAN:ITYPe <IdentifierType>
Selects the format of data and remote frames.
Remote frames are not available in the CAN FD protocol.
Parameters:
<IdentifierT
ype> ANY | B11 | B29
B11
1
1 bit identifier (standard format). The instrument triggers on the
sample point of the IDE bit.
B29
29 bit identifier (extended format). The instrument triggers on the
sample point of the RTR bit.
ANY
The ID type and ID pattern are not relevant for the trigger condi-
tion.