"Frame Start"
Available only for "Variant > 10BASE-T".
Sets the trigger to the start frame delimiter (SFD). The start of frame
(SOF) condition is the occurrence of the preamble; the trigger instant
is after the SFD.
"Pattern"
Available only for "Variant > 10BASE-T".
Sets the trigger to any bit pattern (data) that can be freely specified,
starting from the beginning of the frame. The trigger instant is after
the last bit of the specified data pattern.
"Adv frame "
Triggers on an advanced frame.
"Adv error"
Triggers on any selected errors.
Remote command:
TRIGger<m>:ETHernet:
TYPE on page 2020
Ethernet Variant
Defines the Ethernet protocol variant and transmission speed.
"10BASE-T"
Selects the Ethernet protocol variant 10BASE-T (standard data rate
10 Mbit/s).
Ethernet 10BASE-T and 100BASE-TX (option R&S RT