Protocol analysis
R&S
®
RTO6
900User Manual 1801.6687.02 ─ 05
PACP ← Type
T
riggers on a UniPro PHY Adapter Control Protocol (P
ACP) frame that matches the
specified condition:
Prepare length
PACP Begin
PACP Function ID
Data
Index
CRC
This control frame is used mainly for power mode change and L1.5 link management.
It is also used in scrambling request.
M-PHY and USB SSIC (option R&S R