Protocol analysis
R&S
®
RTO6
903User Manual 1801.6687.02 ─ 05
"Reserved"
Reserved bit command. These bits are reserved for future use.
Remote command:
TRIGger<m>:
MPHY:
LCCType on page 2279
WORD 1/WORD 2/WORD 3/WORD 4
Sets the specified words to be triggered on. The setup for a word consists of the condi-
tion and one or two word patterns.
"Condition"
Sets the comparison condition to a specific value or a range.
"Data Min/Data"
Specifies the value or sets the start value of a range.
In binary format, use the following characters: 1; 0; or X (do not care).
To enter the pattern in other formats use the bit pattern editor
, see
Chapter 13.1.7, "Bit pattern editor", on page 493.
"Data Max"
Sets the maximum value of a range for "Condition" = "In range"/"Out
of range".
Remote command:
For " WORD 1":
TRIGger<m>:
MPHY:
LWONe:CONDition on page 2279
TRIGger<m>:MPHY:LWONe:MIN on page 2280
TRIGger<m>:MPHY:LWONe:MAX on page 2280
For " WORD 2":
TRIGger<m>:MPHY:LWTWo:CONDition on page 2280
TRIGger<m>:MPHY:LWTWo:MIN on page 2281
TRIGger<m>:MPHY:LWTWo:MAX on page 2281
For " WORD 3":
TRIGger<m>:MPHY:LWTHree:CONDition on page 2281
TRIGger<m>:MPHY:LWTHree:MIN on page 2282
TRIGger<m>:MPHY:LWTHree:MAX on page 2282
For " WORD 4":
TRIGger<m>:MPHY:LWFour:CONDition on page 2282
TRIGger<m>:MPHY:LWFour:MIN on page 2283
TRIGger<m>:MPHY:LWFour:MAX on page 2283
TC
Sets the specified Traffic Class (TC) to be triggered on.
TC is used for classifying the traffic flow based on protocol and port number, e.g. TC0
and TC1 are two priority classes with guaranteed link reliability defined and used in L2.
"Data"
Defines the bit pattern of the TC pattern.
In binary format, use the following characters: 1; 0; or X (do not care).
T
o enter the pattern in other formats use the bit pattern editor
, see
Chapter 13.1.7, "Bit pattern editor", on page 493.
Remote command:
TRIGger<m>:MPHY:
TC on page 2283
M-PHY and USB SSIC (option R&S RT
O6-K580 and K570)