1532User Manual 1178.6462.02 ─ 20
Query parameters:
<TrigSource> ANY
For Keysight PNA Compatibility, ANY (and only ANY) is accep-
ted as parameter.
Usage: Query only
TRIGger:WAIT:READy? [<Timeout>]
Returns 1 when the R&S ZNA is "Ready for Trigger", or 0 after the specified <Time-
out>.
Query parameters:
<Timeout> Timeout value (optional, default 1 ms)
Default unit: s
Usage: Query only
7.3.20 New commands for R&S ZNA
● Mixer phase and delay measurements............................................................... 1532
● Advanced port settings........................................................................................1540
● Internal 2nd LO (R&S ZNA-B5)...........................................................................1542
● Other................................................................................................................... 1542
● List of Commands............................................................................................... 1543
7.3.20.1 Mixer phase and delay measurements
Mixer phase calibration (R&S ZNA-K5)
[SENSe<Ch>:]CORRection:POWer:MIXer:IF:ACQuire.....................................................1532
[SENSe<Ch>:]FREQuency:CONVersion:MIXer:PRFimage...............................................1533
SOURce<Ch>:POWer:CORRection:MIXer:IF[:ACQuire]...................................................1533
SOURce<Ch>:POWer:CORRection:MIXer:LO<Stg>[:ACQuire]........................................ 1534
SOURce<Ch>:POWer:CORRection:MIXer:RF[:ACQuire]................................................. 1534
[SENSe<Ch>:]CORRection:POWer:MIXer:IF:ACQuire
Starts the IF receiver calibration (2nd power calibration step for scalar mixer measure-
ments), stores and applies the calibration data.
Note: The receiver calibration relies on the IF source power calibration acquired in
step no. 1. [SENSe<Ch>:]CORRection:POWer<PhyPt>:MIXer:IF:ACQuire is
enabled only after step 1 has been carried out
(SOURce<Ch>:POWer<PhyPt>:CORRection:MIXer:RF[:ACQuire]).
Suffix:
<Ch>
.
Calibrated channel number
SCPI command reference