6 | Electrical connection
80.06.243_iVarioProL-iVarioProXL_IM_en-US 39 / 64
6.4 Connecting the device to the power grid
Notes on the power cable and connection point
n
The manufacturer recommends using a flexible power cable. A rigid power
cable makes the connection more difficult and can impact the position of the
device.
n
The flexible power cable is at least type SOOW 90 °C.
n
The devices are supplied without a power cable. The connection point of the
power cable is on the main contactor in the electrical compartment.
n
You have your own supply cable on hand for the device.
Carrying out the connection
The wires are pushed through a conduit pipe into the electrical compartment.
a A fault-current circuit breaker type A or B is present.
a The electrical compartment is open.
1. Mount a pipe adapter with a diameter of 11/4 inch (not included in the
scope of supply).
2. Feed the wires through the pipe adapter into the electrical compartment to
the connection point. Take care not to damage the conductors.
3. Pull the adapter tight in the opening.
4. Connect the protective conductor to the yellow- green terminal.
5. Connect the red, beige and black conductor directly to contactor K1.
6. Check that the conductors are connected correctly.