EasyManua.ls Logo

Rational iVario Pro L - Manual Cooking Procedures; Conditions, Information, and Warnings; Adjusting Manual Cooking Results; Manual Cooking Parameters

Rational iVario Pro L
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 | Electrical connection
40 / 64 80.06.243_iVarioProL-iVarioProXL_IM_en-US
7. Screw the pipe adapter closed.
8. Connect the wires to the power supply.
>> The grid connection is complete.
Color coding of the terminals
Connection Conductor color Terminal Tool
Phase Black, red and beige L1, L2, L3 Hex key
Protective conduc-
tor
Green PE Slotted screwdriver
6.5 Connect the device for demo mode to the power grid
The demo mode is used for demonstration purposes for the basic functions of
the device.
Observe the following table with the color codings for the connection.
Color coding of the terminals for demo mode
NOTE
Power supply for demo mode
A power supply of at least 190V – 240V AC 50/60Hz is required to run
demo mode.
Connection Conductor color Terminal Tool
Phase Black L1 Hex key
Neutral conductor White L2 Hex key
Protective conduc-
tor
Green PE Slotted screwdriver
The following functions are activated or deactivated in demo mode:
n
Cooking processes are simulated (processes are speeded up)
n
Movement of the pan and device cover is active
n
Heating is deactivated
If the device is connected in demo mode, the following connections are suffi-
cient:
n
One phase
n
One neutral conductor
n
One protective conductor
n
Equipotential bonding
6.6 Closing the electrical compartment
a The power cable is connected to the device.