6 | Electrical connection
44 / 64 80.06.243_iVarioProL-iVarioProXL_IM_en-US
3. Switch the unit on.
4. Use the control panel to select the service level. Navigate to Options (1)
and switch to the relevant supply voltage (2).
1
2
5. Switch the unit off and on again. The changes will now be applied.
6. Run a performance check. Verify that the measured performance data
matches the setting.
>> The power supply has been successfully switched.
6.9 Switch the supply voltage 440 V/480 V
a The device is switched off.
a All voltage sources are switched off via an external circuit breaker.
a The electrical compartment is open.
1. Check the voltage type at the connection.
2. Set the voltage at the 5-pin connector in accordance with the supply volt-
age.