6 | Electrical connection
44 / 72 80.06.231_iVarioProL-iVarioProXL_IM_en-GB
3 AC 400 V Power kW Amp draw A Fuse A Conductor cross-sec-
tion mm²
iVario Pro L 27 39 40 6
iVario Pro XL 41 59 63 10
3 AC 415 V Power kW Amp draw A Fuse A Conductor cross-sec-
tion mm²
iVario Pro L 29 41 50 10
iVario Pro XL 44 61 63 10
3 AC 440 V Power kW Amp draw A Fuse A Conductor cross-sec-
tion mm²
iVario Pro L 25 33 40 6
iVario Pro XL 38 50 50 10
3 AC 480 V Power kW Amp draw A Fuse A Conductor cross-sec-
tion mm²
iVario Pro L 29 35 35 6
iVario Pro XL 44 53 60 10
6.8 Socket in the unit
Version without residual current circuit breaker:
The socket in the unit is equipped with a 10 A fuse. The maximum available
power is 2,3 kW.
Version with residual current circuit breaker:
The socket in the unit is fitted with an integrated RCD, which disconnects the
socket if there is any current leakage.
1. Check the socket in the unit before first use.
2. Regularly check the residual current circuit breaker according to the coun-
try-specific regulations.