9 | Waste water connection
80.06.243_iVarioProL-iVarioProXL_IM_en-US 51 / 64
Installing the drain to the front side of the device
When installing the wastewater drain to the front side of the device, a bracket is
required on the side of the device.
a There is a drainage channel with a waste grating in front of the device.
1. Screw the bracket on to the bottom of the device.
2. Connect the drain pipe and route it through the bracket to the front side of
the device.
3. Observe a minimum distance of 20 mm [3/4 Inch] between the drain chan-
nel and waste water drain. The manufacturer recommends a minimum dis-
tance of 50 mm [2 Inch] to make cleaning easier.
20 mm [3/4 Inch]
>> The drain pipe is installed with an incline of at least 5 % or 3° with the drain
to the front.
Recommendation of the manufacturer for the installation of devices with
substructure with electric height adjustment
a The unit connection kit for drain water type L, XL is on hand.
a The installation altitude on the wall is between 150mm and max. 300mm
(1).
1. Connect an additional ventilation pipe for connections with a flexible hose
(2).