EasyManua.ls Logo

Rational SelfCookingCenter series - Troubleshooting: Power, Cleaning & Gas Issues; Unit Not Functioning After Power On; Foam During Cleaning Process; Incorrect Outlet Installation

Rational SelfCookingCenter series
204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Before you call Service:
198 / 203
of fat are cooked frequently or if the
drop on the outlet pipe is too shallow.
To remedy: Run the outlet pipe as
described in the installation instructions.
Clean the unit regularly with CleanJet
®
+care.
The unit does not
indicate a function
after it is switched on.
External main switch is
switched off.
Switch on at the main switch.
Fuse on the premises’
distribution board has
tripped.
Check the fuses on the premises’
distribution board.
The ambient
temperature after
switching the unit off
remained below 5 °C
(41 °F) for a long time.
Heat the cooking cabinet to above 20
°C (68 °F). The appliance must only
be used in frost-free conditions (see
installation instructions).
Foam forms on the
unit at the top of the
outlet pipe during
CleanJet
®
+care
cleaning.
Water is too soft.
Please notify Customer Service.
The outlet is not
installed correctly.
Install the outlet as described in the
installation manual.
The run time is
suddenly incremented
once more during
a CleanJet
®
+care
process.
The CleanJet
®
+care
process is interrupted.
Make sure that the air baffle and the
grid shelves are fixed correctly in the
cooking cabinet. There must be no
containers or sheets in the cooking
cabinet during the CleanJet
®
+care
process.
Device indicates
“Please replace filter”.
The air filter is soiled. Please replace the air filter. See also
the “Maintenance” section. Press the
“back” arrow to confirm the message.
The gas unit indicates
“change polarity”.
The power supply is
not connected with the
correct polarity.
If the gas unit is connected to a socket,
remove the connector and turn through
180°.
Have an electrician permanently
connect the unit with the correct polarity
(without a connector).

Table of Contents