Model
MAC-12000
MAC-9000
Cooling Capacity 12000 Btu (3,53 Kw) 9000 Btu (2,63 kW)
Heating Capacity
8000 Btu (2,58 kW) 7000 Btu (2,05 kW)
Power Supply
220 240 V; 50 Hz 220 240 V; 50 Hz
Cooling
Rated Input Power/Current
1357 W
1010 W
Hrating
Rated Input Power/Current
1020 W
843
Noise Level
65 dB(A) 65 dB(A)
Maximum Refrigerant Charge
R290/230 g R290/230 g
Net Weight
26,0 kg 25,5 kg
Maximum Design Pressure
Exhaust
Suction
1,8 MPa
0,6 MPa
1,8 MPa
0,6 MPa
Minimum Room Size
10 m
2
10 m
2
Fuse type and rating˖
5ET/SMT, AC 250V,
3.15A
5ET/SMT, AC 250V,
3.15A
The Max operation temperature for the air conditioner
Cooling: 35/24; heating:20/12 ; Temperature
operation range: 7-35.