CHAPTER 4
16 AGCO RoGator C-Series RG900, RG1100, RG1300 Hawkeye® Installation Manual
FIGURE 2. Green Coated and Brown/Gray O-Rings
2. Thread the fly nut onto the nozzle body.
3. Orient the nozzle control valve so that the label is easily readable.
4. Hand tighten the swivel nut to secure the nozzle control valve to the nozzle body. Do not over tighten.
NOTE: Frequently check the nozzle control valve fly nuts to ensure they are secure.
PROSTOP-E WITH WILGER NOZZLE BODY ASSEMBLY
NOTE: For kit numbers ending in 206 - 208, the Hawkeye system will control the Hypro ProStop-E in addition
to the NCV. In order to accommodate both valves, a Wilger dual drop nozzle body is installed along
with an adapter for the ProStop-E adapter.
1. Install the four O-rings into the ProStop-E adapter.
FIGURE 3. ProStop-E Adapter O-Ring Installation
2. Remove the ProStop-E valve from the Hypro nozzle body by removing the U-clip that attaches it to the
threaded nut.
NOTE: Leave the ProStop-E connected to the existing cabling.
3. Remove the Hypro Nozzle body from the boom tubing.
Green Coated
Brown/Gray
Straight Nozzle Body
Turret Nozzle Body
#2-011
#2-117
#2-116
#2-111

Table of Contents

Other manuals for Raven Hawkeye