CHAPTER
5
P/N 016-0171-655 Rev. D 25
CHAPTER 5
ISOBUS ECU MOUNTING AND
CONNECTION
PRODUCT CONTROLLER II ECU INSTALLATION
BEST PRACTICES AND RECOMMENDATIONS
Do not connect battery leads until all cables are installed and connected.
If a protected mounting location is not available on the equipment, mount the Hawkeye
®
product controller II
ECU with the connectors facing down toward the ground to help keep moisture from accumulating in the ECU.
ELECTRICAL BOX PREPARATION
1. Locate the electrical box on the right side of the machine, between the axles and remove the cover.
FIGURE 1. RoGator 1300 Electrical Box Location
2. Locate the Raven Product Control Node.
3. Use a socket and socket extension to loosen the bolt securing the node mounting plate and remove the plate
from the electrical box.
NOTE: The mounting plate will be modified to mount the Product Controller II ECU in the Mounting Plate
Preparation and ECU Installation section on page 28.
Machine
Electrical Box