CHAPTER 5
26 AGCO RoGator C-Series RG900, RG1100, RG1300 Hawkeye® Installation Manual
FIGURE 2. Node Mounting Plate Modifications
4. Remove the bolts securing the Product Controller node to the mounting plate.
5. Remove the Raven Product Controller Node if installed. This step is not needed on AGCONTROL systems.
6. Locate the C180 connectors (RVN PWR) and C190 (RVN SIGNALS) and disconnect the Product Controller Node
jumper cable connections. The jumper cable can be set aside with the Product Controller Node.
FIGURE 3. Power and Signal Connections
7. For signals to reach the C190 connector, complete step a through step d. If it is a Raven controlled machine, it
may already be connected.
Raven AutoBoom
Node
Raven Product
Controller Node

Table of Contents

Other manuals for Raven Hawkeye