APPENDIX A
SIDEKICK PRO™ ICD
INSTALLATION
SIDEKICK PRO ICD CONNECTIONS TO PCB
Connecting the Sidekick Pro™ ICD pump to the Hawkeye system is done via CANBUS PCB located behind the
node enclosure on the right-hand side of the machine.
For machines that do not already have injection pumps, Raven cables P/N 115-0172-443 and P/N 115-0172-444 are
required. For systems that have Raven CAN Sidekick™ Pro pumps installed, simply follow the instructions below.
For systems with AGCONTROL, Sidekick Pro™ ICD pumps are installed and cables are connected.
1. Locate the PCB located on the above the axle on right-hand side of the machine.
FIGURE 1. Rear PCB Location
2. Remove the cover plate.
3. On the PCB, connect the “CAN 4 to BOOM” connector on AGCO harness 596775D1 into the second receptacle
in the top row. Refer to Figure 2 on page 38.