CHAPTER 4
26 Hawkeye Nozzle Control Operation Manual
TOOLS MENU SETTINGS DEFINITIONS
EQUIPMENT SETTINGS TAB
To access the Equipment Settings Menu:
1. Open the VT Menu and select the Hawkeye Menu button.
2. Select the Tools Menu softkey along the right side of the display.
3. Select the Equipment Settings tab along the top of the display. The following settings may be viewed or
modified:
TOTAL AND SECTION WIDTH DISPLAYS
Total Width. The total width value displays the sum of the currently programmed section widths.
Section Widths. The widths of individual sections configured for the Hawkeye nozzle control system will be
displayed below the total width.
NOTE: Restart the calibration wizard to adjust or modify the section widths or the total width of the
implement.
Switch Mapping. Sections mapped to a compatible switch box for manual section control will display using
different color section width displays. Touch the Help icon on the Equipment Settings prompt to view a switch map
legend.
NOTE: To configure section switch mapping, an ISOBUS boom interface/speed sense ECU, Raven ISOBUS
switch box, or a bridge ECU must be connected with the Hawkeye system. To configure switch
mapping, restart the calibration wizard and refer to the Section and Switch Setup section on page 13
for assistance with mapping sections to switch box functions during the calibration wizard.
TOTAL NOZZLE COUNT DISPLAY
The number of nozzles detected on the Hawkeye nozzle control bus during the calibration wizard will be displayed
in this field. If the nozzle count does not match the expected number of nozzles connected to the system,
troubleshoot the nozzle control valve bus and restart the calibration wizard. Refer to Chapter 8, Troubleshooting,
for additional troubleshooting assistance.
SECTION CONTROL MODE
Use the Section Control drop down field to select the section control mode (Virtual, Boom Valve, or HD).
• Basic section control will split the boom based on the number of sections that were entered in the calibration
wizard. AccuBoom will open/close the section valves as well as NCV’s.
• Total and Section Width • Tip Size
• Total Nozzle Count • Nozzle Control Mode
• Nozzle Spacing • Fence Rows
•Injection Wizard •Calibration NCV’s
•Switch Mapping •Section Control Mode
Hawkeye
Menu
Tools Menu
Equipment
Settings
VT Menu