CHAPTER 4
34 Hawkeye Nozzle Control Operation Manual
TANK LEVEL
Enter the current tank level. This feature may be used to manually set the tank level at a level different from the
capacity value, adjust the product volume if products are added through the top of the tank, or to correct the tank
volume for a known volume of product added to the tank.
LOW TANK LIMIT
Enable the Low Tank feature and enter the desired volume threshold at which an alert will be displayed for low
tank condition. Either enter the volume manually upon refilling or use the tank flowmeter to automatically monitor
the tank level.
NOTE: To provide low tank alarms during field applications, ensure the Low Tank option is enabled on the
Alarms Setup screen. Refer to the System Settings Tab - Alarm section on page 34 for additional
assistance with enabling the low tank alarm.
FILL METER CALIBRATION VALUE AND UNITS (MAIN HAWKEYE PRODUCT ONLY)
The fill meter calibration, or meter cal, value and units may be found on the tag attached to the flow meter
installed in the tank fill system. Be sure to select the appropriate units for the flow meter calibration to ensure
proper calibration of the tank fill system.
NOTE: Raven flow meters use a meter cal in pulses per 10 gallons [37.9 L].
Copy the information from the tag for future reference as tags may fade or be lost during operation.
MAX TANK FILL PWM
The maximum PWM the product pump will run at while filling the product tank while using the remote tank fill
feature.
SYSTEM SETTINGS TAB - ALARM
To access the Alarm Settings Menu:
1. Open the VT Menu and select the Hawkeye Menu button.
2. From the home screen, select the Tools Menu softkey along the right side of the display.
3. Select the System Settings tab along the top of the display.
4. Select the Alarm Settings button. The following information will display for the product number shown at the
top of the screen:
Minimum Pressure Pop Up Alarms (Injection)
High Inlet Vacuum (Injection) Pump Efficiency Limit (Injection)
Off Rate Limit (Injection and Hawkeye) Off Target Pressure Percent
Low Tank Limit (Injection and Hawkeye) System Change Detection
System Efficiency Limit (Hawkeye)
Hawkeye Menu
Tools Menu
System
Settings
Alarm
Settings
VT Menu
Alarm
Settings