P/N 016-0171-584 Rev. D 39
HAWKEYE™ NOZZLE CONTROL AND SIDEKICK PRO ICD SETUP
PRODUCT TYPE
Select Water Based or Fertilizer. Hawkeye will compensate for the different flow characteristics of each liquid.
NOTE: The meter cal may need to be adjusted when changing product types.
SYSTEM SETTINGS TAB - PRESSURE
To access the Pressure Settings Menu:
1. Open the VT Menu and select the Hawkeye Menu button.
2. Select the Tools Menu softkey along the right side of the display.
3. Select the System Settings tab along the top of the display.
4. Select the Pressure Settings button. The following information will be available:
* Will only show when a transducer is connected.
RESPONSE RATE
The response rate has a range of 1 to 100 and the setting determines how aggressively the target pressure is
controlled. Increasing the value will cause the system to respond more quickly. Decreasing the value will create a
slower response. Consider increasing the value is the system is slow to reach the target pressure value. The default
product control response rate is 35.
MINIMUM PRESSURE
The minimum pressure feature requires a pressure transducer to monitor product pressure during application and
will allow the operator to set the lowest tolerable pressure during field operations. If the application system
reaches the minimum pressure, the VT will display an alert and the application system will maintain the flow rate to
keep the monitored pressure consistent and to maintain the spray pattern. Default is 20 PSI.
NOTE: The minimum pressure feature may result in higher than desired application rates. If the minimum
pressure feature will be used during field operations, be sure to enter a value that will not interfere
with normal target rates during field application.
MAXIMUM PRESSURE
The maximum pressure feature requires a pressure transducer to monitor product pressure during application and
will allow the operator to set the highest allowable pressure during field operations. Enter the maximum desired
pressure for the system. Upon exceeding maximum pressure, an alert will display, and the flow control will be
Response Rate Minimum Pressure
Maximum Pressure Boom Pressure Calibration*
Advanced Pressure Calibration*