CHAPTER 5
50 Hawkeye Nozzle Control Operation Manual
DTC ALARMS STATUS INDICATOR
The alarm indicator provides a visual status of the Hawkeye Nozzle Control System and Sidekick Pro ICD injection
pump alarms during field applications. The alarm status indicator provides the following display states:
NOTE: Touch the Alarms Status indicator to quickly access the diagnostic trouble code (DTC) List and review
any current or previous alarm condition information. Refer to Chapter 8, Troubleshooting, for
additional assistance with diagnostic trouble codes and using the DTC list.
MASTER SWITCH STATUS
If a Raven ISOBUS switch box, or another compatible master switch, is connected to the
Hawkeye nozzle control system, the current status of the master switch will be displayed in the
control mode area. This is a display only and the physical switch must be used to toggle the
system master on or off during field applications.
TANK VOLUME INDICATOR
The system provides a calculated volume of product
remaining in the tank as a tank indicator in the application
information area. Select this indicator to access the Tank Fill
Config prompt.
NOTE: A tank capacity value must be entered to allow the tank volume indicator to display the tank level.
VOLUME APPLIED
The field volume tally is displayed if there are no injection products for quick reference of the volume of
product dispensed during a field operation.
NOTE: Tally registers from the softkeys area and refer to Chapter 6, Tally Registers, for additional assistance
with using the field and total volume registers.
SECTION STATUS DISPLAY
The Hawkeye system provides the status of each
configured section on the home display. For standard
Hawkeye section control, or Hawkeye Virtual Section
mode, the boom valve section will be a rectangle
above triangles representing the nozzle control
sections. The triangles will change color when the
section is turned on. For Hawkeye HD mode, the
OK. The system status is normal and no alarm conditions are currently
present.
Caution. A minor alarm condition has been detected. The control system is
operating normally, however, the system has detected that a condition exists
which could impact the current application.
Critical. A critical system condition has been encountered. The control
system is not responding as expected and the operator should cease
application and troubleshoot the issue before resuming operations. The
system will not apply in this state
Hawkeye HD
Section Off
or Section
Disabled
Off On
Hawkeye HD
Section On