CHAPTER 8
64 Hawkeye Nozzle Control Operation Manual
3132
.1 System pressure not detectable.
1. Activate product pump.
2. Check for system leaks.
3. Increase pump output to maintain a boom
pressure above 2 PSI [13.8 kPa].
.4 Pressure transducer not detected
1. Check the pressure transducer connection.
2. Check the transducer cabling for damage and
replace the cable if necessary.
.13
Pressure transducer not
calibrated
1. Refer to theTools Menu Settings Definitions
section on page 26 for assistance with the
pressure transducer calibration.
.16
Monitored system pressure
higher than the target pressure
deadband
1. Reduce the equipment speed.
2. Refer to the Pressure 1 and 2 Presets section
on page 36 for assistance with setting or
adjusting the target pressure.
3. Refer to the System Settings Tab - Pressure
section on page 39 for assistance with setting
or adjusting the off pressure percent.
.18
Monitored system pressure lower
than the target pressure
deadband
1. Increase the equipment speed.
2. Refer to the Pressure 1 and 2 Presets section
on page 36 for assistance with setting or
adjusting the target pressure.
3. Refer to the Pressure 1 and 2 Presets section
on page 36 for assistance with setting or
adjusting the off pressure percent.
3132
.15
Monitored system pressure
higher than maximum pressure
set-point
1. Reduce the equipment speed.
2. Refer to theSystem Settings Tab - Pressure
section on page 39 for assistance with
adjusting the maximum pressure set-point.
.17
Monitored system pressure lower
than minimum pressure set-point
1. Increase the equipment speed.
2. Refer to the System Settings Tab - Pressure
section on page 39 for assistance with
adjusting the minimum pressure set-point.
4305 .2
Equipment speed is below
operational range
1. Increase vehicle speed above 0.5 mph [0.8
km/h].
4985 .9 No yaw rate
1. Recalibrate the ECU gyro.
2. Contact a local Raven dealer for additional
assistance.
Code ID Description Recommended Actions