Raven Hawkeye - 1. Refer to the “Tools Menu Settings Definitions” on page 26 for assistance with pressure transducer calibration.; 1. A new injection pump was detected.; 1. A detected injection pump has lost communication. Check the CAN connections of the injection device.; 2. Connect the Raven Service Tool to the ISOBUS and verify communication.

Default Icon
136 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 8
68 Hawkeye Nozzle Control Operation Manual
523192
.13
Sparge pressure transducer not
calibrated
1. Refer to the Tools Menu Settings Definitions”
on page 26 for assistance with pressure
transducer calibration.
.14 New injection pump detected 1. A new injection pump was detected.
.15
Injection pump lost
communication
1. A detected injection pump has lost
communication. Check the CAN connections
of the injection device.
2. Connect the Raven Service Tool to the
ISOBUS and verify communication.
523906 .17
Equipment speed below the
speed range (single nozzle)
1. Increase equipment speed to the range
displayed on the Hawkeye home screen. Refer
to the Hawkeye Upper Home Screen section
on page 46 and Hawkeye Lower Home
Screen section on page 48 for assistance with
the information provided on the home
screen.
523907 .17
Equipment speed below the
speed range (multiple nozzles)
1. Increase equipment speed to the range
displayed on the Hawkeye home screen. Refer
to the Hawkeye Upper Home Screen section
on page 46 and Hawkeye Lower Home
Screen section on page 48 for assistance with
the information provided on the home
screen.
523908 .15
Equipment speed above the
speed range (single nozzle)
1. Reduce equipment speed to the range
displayed on the Hawkeye home screen. Refer
to the Hawkeye Upper Home Screen section
on page 46 and Hawkeye Lower Home
Screen section on page 48 for assistance with
the information provided on the home
screen.
523909 .15
Equipment speed above the
speed range (multiple nozzles)
1. Reduce equipment speed to the range
displayed on the Hawkeye home screen. Refer
to the Hawkeye Upper Home Screen section
on page 46 and Hawkeye Lower Home
Screen section on page 48for assistance with
the information provided on the home
screen.
523910 .1
Nozzle power/temperature error
(single)
1. Nozzle control valve has exceeded safe
operating temperature threshold. Check for
clogs in valve or associated plumbing.
523911 .1
Nozzle power/temperature error
(multiple)
1. Nozzle control valve has exceeded safe
operating temperature threshold. Check for
clogs or restrictions in valves or associated
plumbing.
524080 .31
Lost communication with switch
box
1. Check Raven ISOBUS switch box connections.
2. Connect the Raven Service Tool to the
ISOBUS and verify communication.
3. Verify the power LED is on.
524081 .13 Switchbox not calibrated
1. A switchbox was added after calibration was
complete. Re-calibrate the system with the
switchbox connected.
Code ID Description Recommended Actions