5
Manual No. 016-3001-015 Rev. C 115
Using the OmniSeed Viper Pro System
The Tally Registers screen displays the following for each product node or control channel:
• Total Volume (Ttl Vol)
• Field Volume (Fld Vol)
• Tank Volume (Tnk Vol)
• Total Area (Ttl Area)
• Field Area (Fld Area)
This screen also displays the overall distance traveled by the vehicle as calculated by the Viper Pro using the
speed sensor and programmed speed cal.
Touch the Next button on the Tally Registers screen to view the Odometer screen. Continue touching the Next
button to view the Tally Registers for each product control node in the Viper Pro CANbus system.
Resetting the Tally Registers
Selecting the Reset button for any group of totals on the Tally Registers screen will reset the selected tally for
all nodes at the same time.
For example, touching the reset button above the field volume tally with three product nodes in the system, the
field volume for all three nodes will be reset to zero. Touch the tank volume reset button to reset the tank or bin
volumes to the preset volume value.
Note: Review the Feature Settings Area for Granular Products section on page 144, the Feature
Settings Area for Liquid Products section on page 147 or the following Setting or Resetting
Distance and Individual Nodes section for information on setting the tank volume.