Manual No. 016-3001-015 Rev. C 141
Advanced Settings and Features
7
The following information displays are for reference and monitoring purposes only:
Fan/Pump RPM Display. The fan or pump RPM is a display only. This read out displays the fan RPM if a fan
sensor is being used with a granular application or a pump RPM if a pump sensor is equipped for a liquid
application.
Speed Display. Speed is a display only. The speed shown in this area is the current ground speed of the
vehicle or the entered self test speed. See the Using the Calibration Assistance section on page 245 for
information on entering and using the self test speed feature.
Miscellaneous Settings Screen
Touch within the Miscellaneous area on the CAN Controller Status screen to display the Miscellaneous
Settings screen.
Speed Sensor and Cal. This is the type of speed sensor from which the field computer is receiving speed
signal and the calibration value entered for the selected sensor. Review the Speed Sensor Type and Cal
section on page 38 for details on the sensor type setting or the speed cal value. Refer to the Speed Cal section
on page 245 for information on using the Calibration Assistance feature to refine the current speed cal value.
Speed Source. Set the speed source to ‘Switch Box’ if the speed source is connected to the switch box. Set
the speed source to ‘Air Cart’ if the speed sensor is connected to the air cart node.
Self Test Speed. The self test speed allows the field computer to control product application functions while
the vehicle remains stationary. This feature allows the operator to test or troubleshoot the CAN and product
control systems. For best results, enter a value approximately equal to normal application speeds.
Note: A speed cal must be entered to allow the test speed feature to function.
The test speed will reset to zero if the field computer receives a pulse from the actual speed
sensor. To keep the test speed from disengaging, disconnect the speed sensor from the system.