APPENDIX D
96 RCM - Sprayer and Hawkeye® 2 Calibration and Operation Manual
4. Spray the contacts again with the deoxidizing agent. This will rinse out debris.
5. Remove all residue of deoxidizing agent from the connection. Not removing deoxidizing agent can damage
the connector seal.
6. Dry out the connection with dry, compressed air. Dust Off Electronics Duster (P/N 222-4001-007) is
recommended however, if unavailable, alternate compressed air sources can be used. If using compressed air
from a large volume air compressor, be sure the lines are free of moisture.
FIGURE 2. Compressed Air Used to Dry Connector
7. If not already applied, apply a single, short burst of corrosion inhibitor such as CorrosionX HD (P/N 222-0000-
020) to the NCV2 connection. Be sure the corrosion inhibitor has coated the NCV2 contacts and recessed
portions of the connector.
NOTE: To determine whether corrosion inhibitor has been applied, inspect for a thick liquid in the bottom of
the connector as shown in the image below.
CorrosionX may also be purchased from the manufacturer website:
https://www.corrosionx.com/products/corrosionx-heavy-duty.