CHAPTER 2
6 RCM - Sprayer and Hawkeye® 2 Calibration and Operation Manual
RCM - SPRAYER FEATURES
OPERATION MODES
The RCM - Sprayer with Hawkeye® 2 control system can be configured in several different modes to fit the
application.
TABLE 1.
Operation Modes and Compatible Features
Bypass (Conventional) Mode. The RCM - Sprayer with Hawkeye® 2 mode will control to a target flow, but the
nozzle control valves on the system are disabled. A secondary flow outlet must be made available at each tip.
NOTE: If NCV2s are not detected, the RCM - Sprayer system will automatically configure in Bypass mode.
Bypass mode may also be selected to revert a system with Hawkeye® 2 NCVs to conventional spray
control.
Only select bypass mode if the nozzle bodies on the implement are set to bypass the Hawkeye® 2
NCVs during operation.
Standard Mode. The RCM - Sprayer with Hawkeye® 2 mode will control to a target flow rate and maintain a
constant target pressure.
Variable Pressure (VP) Mode. This RCM - Sprayer with Hawkeye® 2 mode will control to a target flow rate and
target NCV2 duty cycle by varying the pressure range. This is useful for scenarios where maintaining a constant
target pressure is not a priority such as liquid fertilizer application or where droplet size can be maintained over
a wide pressure range.
High Flow Mode. This RCM - Sprayer with Hawkeye® 2 mode allows both a conventional nozzle and a
Hawkeye® 2 NCV to run simultaneously to achieve higher flow rates.
On/Off Mode. The RCM - Sprayer with Hawkeye® 2 System will hold the NCV2s 100% open during application or
fully closed when not applying. This mode can be used with air induction tips and stream bars.
Modes of Operation
Conventional
/Bypass
Standard
Variable
Pressure (VP)
High
Flow
On/Off
Compatible Features
Direct
Injection
Yes Yes Yes Yes Yes
Wireless
Diagnostics
Yes Yes Yes Yes Yes
Flow Control
Yes Yes Yes Yes Yes
Pressure
Control
No Yes No Yes No
Turn
Compensation
No Yes Yes Yes No
Virtual
Sections
No Yes Yes No Yes
Hawkeye HD
Individual
Nozzle Control
No Yes Yes No Yes