EasyManua.ls Logo

Raven RCM-Sprayer Hawkeye 2 - Select Section; Section Status; Select NCV2; NCV2 Status

Default Icon
124 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 4
32 RCM - Sprayer and Hawkeye® 2 Calibration and Operation Manual
4. Select the NCV2 Readings button on the System Settings page. The following reading displays will be available:
Current and Voltage. Displays the electrical current and voltage at the NCV2. Electrical current should be 0.0
when the NCV2 is off. Refer to the NCV2 Technical Specifications section on page 59 for operating
specifications.
NCV2 Duty Cycle. Displays the output duty cycle for each NCV2. Values should increase or decrease as expected
for similar changes in speed, target rate, turning rate, and when flow offsets are enabled. Values go to zero
when not applying.
Driver and Micro Temp. The internal temperatures of the NCV2 components.
Pump Duty Cycle. The duty cycle of the pump control valve.
Runtime Hours. The total time the NCV2 has been active.
Powered Hours. The total time the NCV2 has been powered on.
NCV2 Serial. The serial number for the NCV2.
Hardware Revision. This is the PCB hardware revision level of the NCV2.
Program Version. The version of software loaded on the NCV2.
CAN Address. The CAN address of the NCV2.
SELECT SECTION
Entered the desired section number to inspect or scroll through the sections with the arrow buttons.
SECTION STATUS
Reflects the current operating status of the NCV2s in the selected section.
Green - All NCV2s in the section are operating normally.
Yellow - One or more of the NCV2s in the section have an error and may need inspection.
Red - One or more of the NCV2s in the section are offline and may require inspection.
SELECT NCV2
Enter the desired NCV2 number to inspect or scroll through the NCV2s with the arrow buttons.
NCV2 STATUS
Reflects the current operating status of the selected NCV2.
Green - NCV2 is operating normally.
Yellow - NCV2 has an error and may need inspection.
Red - NCV2 is offline and may require inspection. May also indicate that the system is set to the
NCV2 Bypass control mode.

Table of Contents