EasyManua.ls Logo

Raven RCM-Sprayer Hawkeye 2 - Readouts

Default Icon
124 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
Operation: Universal Terminal Definitions 47
OPERATION
(3) Product Rate Control Mode (M/A). Touch the rate control mode button to toggle
the selected product between automatic and manual control modes.
When the system is toggled to the manual control mode, the preset buttons will be
replaced with ± bump buttons. Review the (5) Presets section on page 47 and the (5)
Manual Control section on page 47.
(4) Main Product. The status of the product is displayed on the upper portion of the
Home page. Select the product status button to toggle the main product on or off
during field applications.
NOTE: Both the master switch and the product must be toggled on to apply
product.
If the machine has an additional switch to open a master tank valve and/or turn on the main product
pump, ensure the machine switch is turned on before the on-screen main product button is toggled
on and that the master switch is toggled on to prevent pressure spikes in the system when starting
application. See the Master Switch Status section on page 48 for additional assistance with the master
switch status display if available.
(5) Presets. Rate or pressure preset buttons are shown toward the
upper, right corner of the display below the target rate or target
pressure fields.
Touch the rate or pressure preset buttons to manually toggle
between preset rates or pressures.
Refer to the Rates Setup Tab section on page 37 for additional
assistance with the rate and pressure preset values.
NOTE: Double tap the rate or pressure tab to quickly access the
Rates Setup page and change the set preset values.
(5) Manual Control. When the system is toggled to the manual control mode, the preset buttons are replaced
with ± buttons.
The ± buttons on the Rates tab manually increase or
decrease the main product pump output.
NOTE: The main product pump manual control softkeys are
replaced by the injection pump manual control softkeys
when the injection pump product is selected.
The ± buttons on the Pressure tab increase or decrease
the NCV2 PWM duty cycle.
The system will continue to monitor and display the actual application rate on the home screen.
READOUTS
The readouts area of the RCM - Sprayer Home page is user configurable to allow the operator to set up the
information to be displayed for each product or pressure tab. Review the Display Setup Menu section on page 28
for additional assistance with customizing the information displayed on each tab and for details about the
available readouts.
Product Rate Mode
Auto Manual
Product Status
Off On
Presets
± Buttons

Table of Contents

Related product manuals