CHAPTER 8
54 RCM - Sprayer and Hawkeye® 2 Calibration and Operation Manual
CURRENT SECTION DISPLAY
The current section for which diagnostic information is being displayed is shown at the top of the NCV2
diagnostics prompt. Select the left or right section select arrow buttons to cycle through sections configured for
use with the Hawkeye® 2 nozzle control system.
SECTION NCV2 STATUS
The status of each NCV2 configured for control on the section is displayed at the bottom of the section
diagnostics prompt. The following NCV2 statuses may be displayed while viewing the section diagnostics prompt:
Normal. The NCV2 is functioning normally and no alarm conditions are currently present.
Caution. A minor NCV2 alert condition has been detected. The control system and NCV2 PWM is
operating normally, however, the system has detected that a condition exists which could impact the
current application.
Critical. A critical NCV2 condition has caused the NCV2 to shut down. The NCV2 is not responding as
expected and the operator should cease application and troubleshoot the issue before resuming
operations.
Not Calibrated. The NCV2 section is not calibrated.
NOTE:Refer to Chapter 9, Troubleshooting, for additional assistance with diagnostic trouble codes and
using the DTC list.
INDIVIDUAL NCV2 DIAGNOSTICS
To access individual Hawkeye® 2 NCV2 diagnostic information:
1. Open the UT Menu and select the RCM - Sprayer Menu button.
2. Select the Advanced Diagnostics softkey in the desired section.
3. Select the Advanced Diagnostics button in the upper, left corner of the NCV2 Diagnostics prompt to access the
following diagnostic information for each NCV2:
RCM - Sprayer Menu NCV2
Diagnostics
UT Menu
Advanced NCV2
Diagnostics