Troubleshooting: NCV2 Technical Specifications 59
TROUBLESHOOTING
NCV2 TECHNICAL SPECIFICATIONS
TABLE 2. Hawkeye® 2 Nozzle Control Valve Technical Specifications
CABLE TROUBLESHOOTING
TROUBLESHOOTING NCV2 CABLE CONNECTIONS
Nozzle control valve cable troubleshooting may require the system to be powered on and the NCV2s
disconnected.
Disconnect the boom cable from the NCV2. Hold the connector so that the retention clip is facing toward the 12
o’clock position.
FIGURE 2. NCV2 Cable Connector
U.S. Metric
Dimensions
Height 2.9 in. 7.32 cm
Width 2.7 in. 6.73 cm
Depth 1.6 in. 40 cm
Weight approximately 8.0 oz.
approximately 0.225
kg
Power
Operating
Voltage
10.5 to 36 VDC nominal
Aux Input up to 36 V
Aux Output 12 V up to 125 mA
Input/Output
CAN CANBUS 2.0 Compliant
Max. Operating
Pressure
120 PSI 827.4 kPa
Environmental
Operating
Conditions
14° to 167° F -10 to 75° C
Storage
Conditions
-40° to 185° F -40° to 85° C
Relative Humidity 10 to 95%
Connector
Retention Clip
123
45
678