Troubleshooting: Cable Troubleshooting 61
TROUBLESHOOTING
TROUBLESHOOTING FLOW METER CABLES
Disconnect the extension cable from the flow meter. Hold the extension cable so that the keyway is facing toward
the 12 o’clock position.
FIGURE 3. Flow Meter Extension Cable Pin Diagram (Con-X-All)
TABLE 6.
Flow Meter with Deutsch DT Connector
TABLE 7. Flow Meter with Deutsch DTM Connector
TEST THE FLOW METER CABLE
To test the flow meter cable:
1. Open the UT Menu and select the RCM - Sprayer Menu button.
2. From the home screen, select the Diagnostics softkey along the right side of the display.
3. Select the System Information tab along the top of the display and select the Delivery System option from the
drop-down list toward the top of the page.
4. Monitor the Flow Meter (Hz) value while testing the cable.
5. Toggle at least one section switch and the master switch to the on position.
Pin Function
A+ VDC
B0 VDC
C Signal Out
Pin Function
1Signal
2Ground
35 VDC
Keyway
5 VDC5 VDC
2 o’clock
Ground
10 o’clock
Power
6 o’clock
Signal
RCM - Sprayer Menu Diagnostics System
Information
UT Menu
Delivery
System