Chapter 3
22 Sidekick Pro Installation & Operation Manual
Detecting and Addressing the Motor Control
Node
Review the CAN setup section of the Raven control console manual for detailed CANbus system information.
Alternate Method to Readdress the Injection Motor Control
Node
The Sidekick Pro motor control node may be readdressed using either the process described in the CAN
control console manual, or by the following procedure:
1. Begin readdressing nodes as described in the Raven control console manual.
2. When prompted to readdress the product number for the injected product, pass a metal object across the
calibration sensor located at the point of the white arrow on the side of the node housing.
FIGURE 14. Motor Control Node Calibration Sensor
3. Complete the procedure to readdress nodes as described in the Raven control console manual.
Calibration
Sensor Location