Chapter 7
52 Sidekick Pro Installation & Operation Manual
Error Codes
TABLE 2. Sidekick Pro Error Codes for Viper Pro and Envizio Pro
Error Code Possible Cause Solution
Code 101
Left transducer out
of calibration
Recalibrate pressure transducers.
Faulty left
transducer
Replace left pressure transducer.
Code 102
Right transducer out
of calibration
Recalibrate pressure transducers.
•Faulty right
transducer
Replace right pressure transducer.
Code 103
Flow obstruction in
left intake valve
Perform a pump calibration test. If the pump does not
calibrate properly, remove the left intake cartridge and
perform pump maintenance to clear obstructions.
Faulty left pressure
transducer
Perform a pump calibration test. If the pump calibrates
properly, replace the left pressure transducer.
Code 104
Flow obstruction in
right intake valve
Perform a pump calibration test. If the pump does not
calibrate properly, remove the right intake cartridge and
perform pump maintenance to clear obstructions.
•Faulty right
pressure transducer
Perform a pump calibration test. If the pump calibrates
properly, replace the right pressure transducer.
Code 105
Flow obstruction in
left exhaust valve
Perform a pump calibration test. If the pump does not
calibrate properly, remove the left exhaust cartridge and
perform pump maintenance to clear obstructions.
Faulty left pressure
transducer
Perform a pump calibration test. If the pump calibrates
properly, replace the left pressure transducer.
Code 106
Flow obstruction in
right exhaust
cylinder
Perform a pump calibration test. If the pump does not
calibrate properly, remove the right exhaust cartridge and
perform pump maintenance to clear obstructions.
•Faulty right
pressure transducer
Perform a pump calibration test. If the pump calibrates
properly, replace the right pressure transducer.
Code 107
Clogged pump
strainer
Clean pump strainer and check for obstructions in
injection line between the pump inlet and chemical supply
tank.
Tubing or plumbing
size restriction
Verify the proper size of injection supply tubing is used
between the chemical supply tank and pump inlet.
Chemical too thick Dilute product in chemical supply tank. Some chemicals
may not be applied using a direct injection system.
Code 108
Clogged or
restricted pump
outlet supply lines
Check for restrictions or blockages in outlet supply lines.
Flush the injection system to clear clogs and residue
buildup.
Tubing or plumbing
size restriction
Verify the proper size of injection outlet tubing is used
between the point of injection and pump outlet.
Faulty PSI
transducer
Hand valve closed Check hand valves are open and allow flow from the
injection pump outlet port.
Low injection
pressure