18
2.OTHER DISPLAY FEATURES
1) To display TOTAL AREA covered, momentarily depress .
To "zero out" this total at any time, enter a "0" in this key.
2) To display TOTAL VOLUME sprayed, momentarily depress .
To "zero out" this total at any time, enter a "0" in this key.
3) To display FIELD AREA covered, momentarily depress .
To "zero out" this total at any time, enter a "0" in this key.
4) To display FIELD VOLUME sprayed, momentarily depress .
To "zero out" this total at any time, enter a "0" in this key.
5) To display DISTANCE (feet) [meters] traveled, momentarily depress . To "zero
out" this total at any time, enter a "0" in this key.
6) To display SPEED, momentarily depress .
7) To display VOL/MIN, momentarily depress .
8) To display AREA/HOUR, momentarily depress . This is an actual calculation
of AREA/HOUR at the present speed you are going. It is not an average over a period
of time.
9) To display US, SI, or TU; SP1 or SP2; and C-SD, C-F, C-FC, C-P or C-PC after being
selected, depress .
3.SELF TEST FEATURE
SELF-TEST allows speed simulation for testing the system while vehicle is not
moving. Enter the simulated operating speed in . If 6 MPH [10 km/h] is
desired, enter 6.0 [10.0]. Verify SPEED by depressing . The SELF-TEST
speed will clear itself when motion of vehicle is detected by the Speed Sensor.
A SPEED CAL value of 900 [230] or greater is recommended when operating in this
mode.
NOTE: To prevent nuisance clearing of self-test speed, disconnect speed
connector on back of Console when Radar Speed Sensors are used.