Chapter 9
178 Viper Pro Installation & Operation Manual
Enabling AccuBoom™ Override
The AccuBoom Override feature allows the operator to apply product to a previously covered area during an
active job. This feature is useful when backing into corners during boundary spraying, to start product
application from a complete stop, or to apply additional product on a heavily infested area of the field.
Note: Use the AccuBoom Override when accelerating from a complete stop to allow the valves to open
and allow the application system to develop a proper spray or spread pattern and avoid gaps in
coverage.
1. While in a job, touch the boom area on the main Viper screen. The AccuBoom Control Setup screen
displays.
2. Using the screen keyboard, enter a value, in seconds, in the AccuBoom Override Sec field.
Note: The value previously entered for the AccuBoom Override Seconds field will be automatically re-
entered when starting new jobs or resuming a previous job file.
3. Touch the Activate button to override all boom sections On.
4. The main screen will re-appear with the AccuBoom Override showing in the boom area.
Note: When the field computer is interfacing with a CANbus system controlling 6 products or more, the
AccuBoom Override will not be displayed on the screen.
5. AccuBoom control of all boom sections will be overridden until the time set as the Override Seconds value
expires. Once the set override time has run out, AccuBoom automatic section control will resume for all
boom sections selected for AccuBoom control.