Manual No. 016-0171-122 Rev. I 247
Note: The Viper Pro uses the currently entered product density and spreader constant when performing
the Calibration Assistance wizard. Raven recommends setting any known values prior to
beginning the Calibration Assistance wizard to ensure accuracy of the Viper Pro system.
5. Enter the amount of product to dump during the test as the Desired Weight.
Note: The weight of product in the bin must be equal to or greater than the value entered as the Desired
Weight.
6. Touch the Begin Calibration button. The second Spreader Calibration screen will be displayed.
7. Weigh the machine and enter the total weight of the machine as the Start Weight.
Note: Weight of the machine before and after the dump test or weight of the dumped product may be
used in the Spreader Calibration procedure. If the weight of the dumped product will be used,
enter a value of zero as the start weight.