4.4PowerconnectionNewcSeries
andNeweSeries
D12 25 0-1
1
2
4
5
7
3
8
6
9
1.Multifunctiondisplayconnections.
2.Poweranddatacable.
3.Connectionto12/24Vpowersupply(e7/e7Dis12Vonly).
4.Redcable(positive).
5.Fuse.
6.Blackcable(negative).
7.Videoinputcable.
8.NMEA0183datacables.
9.Shield(drain)wire(thinblackwire;mustbeconnectedtoRF
groundpoint).
Powerdistribution
Raymarinerecommendsthatallpowerconnectionsaremadeviaa
distributionpanel.
Allequipmentmustbepoweredfromabreakerorswitch,with
appropriatecircuitprotection.
Allequipmentshouldbewiredtoindividualbreakersifpossible.
Warning:Productgrounding
Beforeapplyingpowertothisproduct,ensureithas
beencorrectlygrounded,inaccordancewiththe
instructionsinthisguide.
GroundingDedicateddrainwire
Thepowercablesuppliedwiththisproductincludesadedicated
shield(drain)wireforconnectiontoavessel'sRFgroundpoint.
ItisimportantthataneffectiveRFgroundisconnectedtothe
system.Asinglegroundpointshouldbeusedforallequipment.
Theunitcanbegroundedbyconnectingtheshield(drain)wireof
thepowercabletothevessel'sRFgroundpoint.Onvesselswithout
anRFgroundsystemtheshield(drain)wireshouldbeconnected
directlytothenegativebatteryterminal.
Thedcpowersystemshouldbeeither:
Negativegrounded,withthenegativebatteryterminalconnected
tothevessel'sground.
Floating,withneitherbatteryterminalconnectedtothevessel's
ground
Warning:Positivegroundsystems
Donotconnectthisunittoasystemwhichhaspositive
grounding.
Powercable
Thedisplayissuppliedwithacombinedpoweranddatamulticable,
thiscanbeextendedifrequired.
Powercablesavailable
CablePartnumberNotes
1.5m(4.9ft)Straight
poweranddatacable
R62379
1.5m(4.9ft)Right
angledpoweranddata
cable
R70029
Cableextension
Thefollowingrestrictionsapplytoanyextensiontothepowercable:
Cablemustbeofasuitablegaugeforthecircuitload.
Eachunitshouldhaveitsowndedicatedpowercablewiredback
tothedistributionpanel.
Totallength(max)SupplyvoltageCablegauge(AWG)
12V18
0–5m(0–16.4ft)
24V20
12V14
5–10m(16.4–32.8ft)
24V18
12V12
10–15m(32.8–49.2ft)
24V16
12V12
15–20m(49.2–65.5ft)
24V14
Note:Thesedistancesarefora2wirepowercablerunfromthebatteryto
thedisplay(approximatelythedistancefromthebatterytothedisplay).To
calculatetheroundtriplength,doublethegurestatedhere.
Breakers,fusesandcircuitprotection
Thepowercableincludesanin-linefuse.Itisrecommendedthat
youtanadditionalthermalbreakerorfuseatthedistributionpanel.
FuseratingThermalbreakerrating
7Ain-linefusettedwithinpower
cable.
5A(ifonlyconnectingonedevice)
Note:Thesuitablefuseratingforthethermalbreakeris
dependentonthenumberofdevicesyouareconnecting.Ifin
doubtconsultanauthorisedRaymarinedealer.