WirecolorSignal/Description
1
Bespokeswitch
2
OrangeAISSilent+
3
LightGreenAISSilent
1.RuncablefromswitchlocationtoAISunit.
2.Crimporsolderwireconnectionstotheswitch.
3.CrimporsolderswitchwirestotheorangeandlightgreenAIS
silentwiresonthepower/datacable.
4.Ensurecablesareadequatelyshielded.
Powerconnection
Powersupplyprotection
Alwaysprotectthepowersupplybyconnectingthered(positive)
wiretothesupplyviaa5Afuseorequivalentautomaticcircuit
breaker.
Sharingabreaker
Wheremorethan1pieceofequipmentsharesabreakeryoumust
provideprotectionfortheindividualcircuits.E.g.byconnectingan
in-linefuseforeachpowercircuit.
D116 37 -2
2
4 4
1
3
+
-
1
Positive(+)bar
2
Negative(-)bar
3
Circuitbreaker
4Fuse
Wherepossible,connectindividualitemsofequipmenttoindividual
circuitbreakers.Wherethisisnotpossible,useindividualin-line
fusestoprovidethenecessaryprotection.
AIS650ClassBtransceiver63