2.11Troubleshooting
IssueAction
Nopower
Check:
Allpowerconnections
Checkrelevantfuses
Thatpowersupplyisatthecorrectvoltage(12Vor24V)
Nodata
Checkthat:
Connectionsaresecurethroughoutthesystem
TheVHFantennaleadissecurelyconnected.
Novesseldata
AttherelevantRaymarinemultifunctiondisplay:
Placethecursoroverthetargetedvesselandensure
theAISDATAsoftkeyisnotsettoOFF
EnsuretheAISlayerissettoON
EnsuredisplayedtargettypesaresettoALL
NoAISdataChecktheNMEAand/orSeaTalk
ng
outputfromthe
multifunctiondisplaystothetransceiverinput,andensure:
Thewiresarecorrectlyconnected
ThebaudrateforNMEAis38400baud
NMEA2000Sentences
ThereceiversupportsthefollowingParameterGroupnumbers
(PGNs).
PGNTitleSupported
129038
ClassApositionreport
129039
ClassBpositionreport
129793
AISUTCanddatereport
129794
AISclassAstaticand
voyagerelateddata
129802
AISbroadcastsafety
message
129041AtoNpositionreport
129809
AISclassBstaticdata
partA
129810
AISclassBstaticdata
partB
126996
Productinfo
059904
ISOrequest
059392
ISOacknowledge
060928
ISOaddressclaim
065240
ISOaddresscommand
126208
NMEAgroupfunctions
28AIS350/AIS650Installationinstructions