PossiblecausesPossiblesolutions
Damagedcables
1.Checktheunit’sconnectorforbrokenorbentpins.
2.Checkthatthecableconnectorisfullyinsertedintothe
unitandthatthelockingcollarisinthelockedposition.
3.Checkthecableandconnectorsforsignsofdamageor
corrosion,replaceifnecessary.
4.Withtheunitturnedon,tryflexingthepowercablenear
tothedisplayconnectortoseeifthiscausestheunitto
re-boot/loosepower,replaceifnecessary.
5.Checkthevessel’sbatteryvoltage,theconditionofthe
batteryterminalsandpowersupplycables,ensuring
connectionsaresecure,cleanandfreefromcorrosion,
replaceifnecessary.
6.Withtheproductunderload,usingamulti-meter,check
forhighvoltagedropacrossallconnectors/fusesetc(this
cancausetheFishfinderapplicationstostopscrollingor
theunittoreset/turnoff),replaceifnecessary.
Vesselspeedtoohigh
Slowvesselspeedandrecheck.
Bottomtooshallowortoodeep
Thebottomdepthmaybeoutsideofthetransducersdepth
range,movevesseltoshallowerordeeperwatersasrelevant
andrecheck.
Poor/problematicimage
PossiblecausesPossiblesolutions
Vesselstationary
Fisharchesarenotdisplayedifthevesselisstationary;fish
willappearonthedisplayasstraightlines.
Scrollingpausedorspeedsettoo
low
Unpauseorincreasesonarscrollingspeed.
Sensitivitysettingsmaybe
inappropriateforpresent
conditions.
CheckandadjustsensitivitysettingsorperformaSonarreset.
Damagedcables
1.Checktheunit’sconnectorforbrokenorbentpins.
2.Checkthatthecableconnectorisfullyinsertedintothe
unitandthatthelockingcollarisinthelockedposition.
3.Checkthecableandconnectorsforsignsofdamageor
corrosion,replaceifnecessary.
4.Withtheunitturnedon,tryflexingthepowercablenear
tothedisplayconnectortoseeifthiscausestheunitto
re-boot/loosepower,replaceifnecessary.
5.Checkthevessel’sbatteryvoltage,theconditionofthe
batteryterminalsandpowersupplycables,ensuring
connectionsaresecure,cleanandfreefromcorrosion,
replaceifnecessary.
6.Withtheproductunderload,usingamulti-meter,check
forhighvoltagedropacrossallconnectors/fusesetc(this
cancausetheFishfinderapplicationstostopscrollingor
theunittoreset/turnoff),replaceifnecessary.