LEDindicationstatus
LEDcolorLEDcodeStatusUseraction
SolidGreenPowerOn•None(normalpoweruptakes<1minute.)
Green1blink
Normaloperation•None
Amber1blinkTransducer
disconnected
•Ensuretransducercableandconnectionsaresecureandfree
fromdamage.
•Powercycleunittorecovertransducerinformation.
•IfproblempersistscontactRaymarinetechnicalsupport.
Amber2
blinks
Nonetworkdetected•Ensurenetworkispowered.
•Ensurenetworkcableandconnectionsaresecureandfree
fromdamage.
•IfproblempersistscontactRaymarinetechnicalsupport.
Amber3
blinks
Unitoverheating•Ensureinstallationenvironmentiswithinrecommendations.
•Unitwillrecoverwhentemperaturefallswithinspecications.
•IfproblempersistscontactRaymarinetechnicalsupport.
Amber4
blinks
Transducer
overheating
•Ensureinstallationenvironmentiswithinrecommendations.
•Unitwillrecoverwhentemperaturefallswithinspecications.
•IfproblempersistscontactRaymarinetechnicalsupport.
Amber5
blinks
Undervoltage
(<10.2V)
•Ensurepowercableandconnectionsaresecureandfreefrom
damage.
•Ensurepowersupplycablingisconsistentwith
recommendations.
•IfproblempersistscontactRaymarinetechnicalsupport.
38CP450C