16.3T
echnicalspecificationACU-200,ACU-300,ACU-400
A
CU-200ACU-300ACU-400
Drivecurrentoutput
Maximum
continuous15A
atsupplyvoltage
.
Maximum
continuous5Aat
supplyvoltage.
Maximum
continuous30A
atsupplyvoltage.
Driveclutchoutput
Upto2.0Acontinuous,
selectablebetween12
/24V
Noclutchconnection.Upto4Acontinuous
at12Von12V
systems.
Upto4Acontinuous
at24Von24V
systems.
Upto4Acontinuous
at12Von24V
systems.
Connections
Rudderangle
referencesensor
/transducer
.
Sleepswitch.
Power.
Drivemotor.
Driveclutch.
Ground.
Rudderangle
referencesensor
/transducer.
Sleepswitch.
Power.
Solenoiddriveout/
return.
Ground.
Rudderangle
referencesensor
/transducer.
Sleepswitch.
Power.
Drivemotor.
Driveclutch.
Ground.
DigitalInput/Output
(DIO).
Nominalsupply
voltage
12Vor24V
Operatingvoltage
range
10 .8Vto31.2Vdc
P owerconsumption
(standby)main
powersupply
300mA(12/24V)
P owerconsumption
(standby)
SeaTalkng®power
supply
20mA(12V)
Sea Talkng®LEN(Load
EquivalencyNumber)
1
Sea Talkng®Powerout
3Aat12V(fuseprotectedat3A).
Dataconnections
Sea Talkng®
EnvironmentalInstallationenvironment
Operatingtemperature:-20ºCto+55ºC(-4ºFto+131ºF).
S toragetemperature:-30ºCto+70ºC(-22°Fto+158°F).
Relativehumidity:max93%.
Waterproofrating:Dripresistant.
Dimensions
Width:285mm(11.2in).
Height:211.5mm(8.3in).
Depth:64.5mm(2.5in).
126