10.2 Instrument troubleshooting
Problem Applies to Example screenshots Action
Low battery. i40 Bidata
i40 Depth
i40 Speed
i40 Wind
Recharge your vessel's battery as
soon as possible.
Blank display. i40 Bidata
i40 Depth
i40 Speed
i40 Wind
Check fuse / circuit breaker.
Check power supply.
Check SeaTalk cabling and
connector security.
Depth reading ashes when underway.
i40 Bidata
i40 Depth
Ensure the reading stabilizes when
clear of disturbed water (e.g. vessel
wakes, propeller wash etc.).
No data. i40 Bidata
i40 Depth
i40 Speed
i40 Wind
Check the condition of the
transducer cable and security of the
connections.
Check condition of transducer face
and remove any debris.
For i40 wind if true wind speed
information is missing but apparent
wind is present then this could be
due to no speed information via
SeaTalk.
Troubleshooting
53