EasyManua.ls Logo

Raymarine i40 - User Calibration - i40 Speed

Raymarine i40
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9.3Usercalibrationi40Speed
Calibrationproceduresaredependantoninstrument
displayvariant.
Usercalibrationoptionsinclude:
SpeeddisplayresponseDictatestherateat
whichtheinstrumentdisplayrespondstochanges
inspeeddata.
*UnitsforspeedreadingsAssignstheunitof
measureusedforspeedrelatedreadings.
*UnitsfordistancereadingsAssignstheunitof
measureusedfordistancerelatedreadings.
*UnitsforwatertemperatureAssignstheunit
ofmeasureusedfortemperaturerelatedreadings.
*CorrectspeedreadingAssignsanoffsetto
thespeedreading.
Note:*Thesesettingsareonlyavailableonunits
whentheinstrumentstatussettoMaster(see
IntermediateCalibrationfordetailsofchangingthe
displaytobeMasterorRepeater).
Calibratingspeed
Tocalibrateyouri40Speedfollowthestepsbelow.
Duringnormaloperation:
1.SimultaneouslypressandholdtheDownand
Actionbuttonsfor2secondstodisplaytheUser
Calibrationpage.
10
15
20
25
30
35
40
45
50
55
60
5
2
+
D12 4 14 -1
2.PresstheActionbuttontodisplaytheSpeed
Responsepage.
CAL
D12 4 10 -1
3.UsetheUpandDownbuttonstoadjustthe
speedresponsetotherequiredlevel.
Thedefaultlevelis12.Thelevelsavailableare1
to15withlevel1beingtheslowestupdaterate
andlevel15thequickest.
4.PresstheActionbuttontodisplaytheSpeed
unitspage.
CAL
D12 4 11-1
5.UsetheUpandDownbuttonstoselectthe
requiredunitofmeasurementforspeedreadings.
Theunitsofmeasureavailableforspeed
readingsare:
KTSKnots(default)
MPHMilesPerHour
KPHKilometersPerHour
6.PresstheActionbuttontodisplaytheDistance
unitspage.
CAL
D12 4 03 -1
7.UsetheUpandDownbuttonstoselectthe
requiredunitofmeasurementfordistance
readings.
Theunitsofmeasureavailablefordistance
readingsare:
NMNauticalMiles(default)
SMStatuteMiles
KMKilometers
8.PresstheActionbuttontodisplaytheWater
temperatureunitspage.
CAL
D12 4 12 -1
9.UsetheUpandDownbuttonstoselectthe
requiredunitofmeasurementfortemperature
readings.
Theunitsofmeasureavailablefortemperature
are:
°CdegreesCelsius(default)
°FdegreesFahrenheit
10.PresstheActionbuttontodisplaytotheSpeed
CalibrationFactorpage.
CAL
D12 3 98 -1
11.UsetheUpbuttontoincreasethecalibration
factorvalue,ortheDownbuttontodecreasethe
calibrationfactorvalueuntilthedisplayedspeed
iscorrect.
Thedefaultcalibrationfactoris1.00.The
calibrationfactorcanbesetfrom0.25to2.50.
12.Alternatively:
i.SimultaneouslypressandholdtheUpand
DownbuttonstodisplaytheSpeedOver
Ground(SOG)page.
CAL
D12 409 -1
+
Note:TheSOGpageisonlydisplayedifSOG
dataisavailableonSeaTalkandthevesselspeed
isgreaterthan0.5kts.
ii.Then,inconditionsofzerotideandcurrent,
presstheUpbuttonfor3secondstoapply
theSOGvalueasthespeedreading.
13.T osaveyoursettingsandreturntonormal
operationfromanypage,simultaneouslypress
andholdtheDownandActionbuttonsfor2
seconds.
i40Speed
53

Table of Contents

Other manuals for Raymarine i40

Related product manuals