10.3Usercalibrationi40Wind
Calibrationproceduresaredependantoninstrument
displayvariant.
Usercalibrationoptionsinclude:
WindAngledisplayresponseDictatesthe
rateatwhichtheinstrumentdisplayrespondsto
changesinwindangledata.
WindSpeeddisplayresponseDictatesthe
rateatwhichtheinstrumentdisplayrespondsto
changesinwindspeeddata.
UnitsforwindspeedreadingsAssignstheunit
ofmeasureusedforwindspeedrelatedreadings.
LinearizationPerformswindtransducer
linearization.
AlignmentAlignswindtransducertovessel
heading.
Note:*Thesesettingsareonlyavailableonunits
whentheinstrumentstatussettoMaster(see
IntermediateCalibrationfordetailsofchangingthe
displaytobeMasterorRepeater).
Calibratingwind
Youwillneedtobeunderway,withsufcientspace
toturninalargeslowcircleunhindered.Conditions
shouldbecalm(i.e.aslightsea)andasteady
breeze.Trytoensurethevesselisnotrollingor
pitchingtoomuch.
Duringnormaloperation:
1.SimultaneouslypressandholdtheDownand
Actionbuttonsfor2secondstodisplaytheUser
Calibrationpage.
10
15
20
25
30
35
40
45
50
55
60
5
2
+
D12 4 20 -1
2.PresstheActionbuttontodisplaythesetWind
AngleResponsepage.
CAL
D12 4 17 -1
3.UsetheUpandDownbuttonstoadjustthewind
angleresponsetotherequiredlevel.
Thedefaultlevelis12.Thelevelsavailableare1
to15withlevel1beingtheslowestupdaterate
andlevel15thequickest.
4.PresstheActionbuttontodisplaytheWind
SpeedResponsepage.
CAL
D12 4 18 -1
5.UsetheUpandDownbuttonstoadjustthewind
speedresponsetotherequiredlevel.
Thedefaultlevelis12.Thelevelsavailableare1
to15withlevel1beingtheslowestupdaterate
andlevel15thequickest.
6.PresstheActionbuttontodisplaytheWind
SpeedUnitspage.
CAL
D12 4 19 -1
7.UsetheUpandDownbuttonstoselectthe
requiredunitofmeasurementforwindspeed
readings.
Theunitsofmeasureavailableforwindspeed
readingsare:
KTSKnots(default)
M/SMetersPerSecond
8.PresstheActionbuttontodisplaytheLinearize
Transducerpage.
CAL
D12 4 05 -1
Note:If5pdisdisplayedonthelinearize
transducerpagethewindspeedisoutsideofthe
rangesuitableforlinearization.
9.Keepthevesselspeedbelow2ktsandbeginto
turnthevesselinacircle.
10.PresstheUpbuttontobeginlinearization.
11.Youwillberequiredtoperformaminimumof2
completecircles.
x 2
D12415-2
Analarmwillsounduponsuccessfulcompletion.
12.Sailthevesseldirectlyintothewind.
13.PresstheActionbuttontodisplaytheAlign
Transducerpage.
CAL
D12 4 16 -1
14.UsetheUpandDownbuttonstoadjustthevalue
untilthewindanglepointerissettozero.
CAL CAL
D13079-1
15.T osaveyoursettingsandreturntonormal
operationfromanypage,simultaneouslypress
andholdtheDownandActionbuttonsfor2
seconds.
i40Wind59