EasyManua.ls Logo

Raymarine i60 wind - User Calibration

Raymarine i60 wind
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.1Usercalibration
Thei60CHinstrumentdisplayisarepeaterdisplay
andassuchdoesnotrequirecalibration,thesteps
belowapplytothecalibrationofthei60Wind
instrumentonly.
Usercalibrationoptionsinclude:
WindangleoffsetAssignsanoffsettothewind
anglereadings.
UnitsforWindspeedreadingsAssignstheunit
ofmeasureusedforwindspeedrelatedreadings
AutomaticLinearization
Thewindtransducercanlinearizeitselfautomatically
undercertainconditions.
ForAutomaticLinearizationtobeperformedCAL
mustbeashingonthedigitaldisplay.CALis
displayedforapproximately30secondsafterpower
onunderthefollowingconditions:
Atrstpoweron,afterinstallation
Atpoweron,afterafactoryreset.
Toperformtheautomaticlinearizationthevesselwill
needtobeunderway,withsufcientspacetoturnin
largecirclesunhindered.Thewindspeedmustbe
sufcienttoholdthevanetowindwhilstthevesselis
turning.Thevesselmustbeturnedslowlythroughat
least2completecircles.
x 2
D12415-2
Thisprocedureautomaticallylinearizesthewind
vane.Asuccessfullinearizationisindicatedbythe
digitaldisplayashingandabuzzersoundingthree
beeps
AccessingtheUserCalibrationMenu
TheUserCalibrationMenucanbeaccessedby
followingthestepsbelow.
Duringnormaloperation:
1.PressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately
2seconds,untiltheUserCalibrationpageis
displayed.
+
D12488-2
10
15
20
25
30
35
40
45
50
55
60
5
2
Display
True /App
Aligningthewindtransducer
FromtheUserCalibrationMenu:
1.PresstheDisplaybuttonuntiltheWindAngle
Offsetpageisdisplayed(1pressfromtheUser
Calibrationpage).
D12489-2
Display
2.Sailyourvesseldirectlyintothewindandadjust
theanalogpointertozero,usingtheVMGand
Tackbuttons.
D12490-2
VMG Ta c k
TheVMGbuttonwilldecreasethecurrentvalue
andtheT ackbuttonwillincreasethecurrent
value.Asyoudothis,thewindangleoffset
showstheamountofcorrectionyouhaveapplied.
3.ToexittheUserCalibrationMenuatanytime
pressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately2
seconds.
Selectingtheunitofmeasureforwindspeed
readings
FromtheUserCalibrationMenu:
1.PresstheDisplaybuttonuntiltheWindSpeed
Unitspageisdisplayed(2pressesfromtheUser
Calibrationpage).
D12491-2
Display
2.UsetheVMGorTackbuttonstoselectthe
requiredunitofmeasureforwindspeedreadings.
Theavailableunitsofmeasureforwindspeed
are:
KTS(default)Knots
M/SMeterspersecond
3.ToexittheUserCalibrationpagesatanytime
pressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately2
seconds.
38i60

Table of Contents

Related product manuals