1.PresstheDisplaybuttonuntiltheWindAngle
Responsepageisdisplayed(1pressfromthe
UserCalibrationAccessMenupage).
2.UsetheVMGandTackbuttonstosetthe
requiredlevelforWindAngleResponse.
Thedefaultlevelis12.Thelevelsavailableare1
to15withlevel1beingtheslowestupdaterate
andlevel15thequickest.
Note:T oexittheDealerCalibrationpagesatany
time,pressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately2
seconds.
SettingtheresponsedelayforWindSpeed
readings
FromtheUserCalibrationMenuAccesspage:
1.PresstheDisplaybuttonuntiltheWindSpeed
Responsepageisdisplayed(2pressesfromthe
UserCalibrationAccessMenupage).
2.UsetheVMGandTackbuttonstosetthe
requiredlevelforWindSpeedResponse.
Thedefaultlevelis12.Thelevelsavailableare1
to15withlevel1beingtheslowestupdaterate
andlevel15thequickest.
Note:T oexittheDealerCalibrationpagesatany
time,pressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately2
seconds.
SettingtheresponsedelayforVMGreadings
FromtheUserCalibrationMenuAccesspage:
1.PresstheSpeedbuttonuntiltheVMGResponse
pageisdisplayed(3pressesfromUser
CalibrationMenuAccesspage).
2.UsetheVMGorTackbuttonstosettherequired
levelforVMGresponse.
Thedefaultlevelis12.Thelevelsavailableare1
to15withlevel1beingtheslowestupdaterate
andlevel15thequickest.
Note:T oexittheDealerCalibrationpagesatany
time,pressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately2
seconds.
SettingthewindspeedCalibrationFactor
Ifyoundthatyourwindspeedreadingsdeviatefrom
areferencedwindspeedsourcethenaCalibration
Factorcanbeappliedtoreducethedeviation.
FromtheUserCalibrationMenuAccesspage:
1.PresstheDisplaybuttonuntiltheCurrentWind
Speedpageisdisplayed(4pressesfromthe
UserCalibrationMenuAccesspage).
2.UsetheVMGandTackbuttonstoadjustthe
CalibrationFactortothedesiredvalue.
WhentheVMGandTACKbuttonsarenot
beingpressedthescreenwillrevertbackto
CurrentWindSpeedpagetoenableyoutosee
whatchangetheCalibrationFactorhasonthe
display’sWindSpeedreading.
Note:Toexitthedealercalibrationpagesatany
timepressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately2
seconds.
EnablinganddisablingBoatShowMode-i60
FromtheUserCalibrationMenuAccesspage:
1.PresstheDisplaybuttonuntiltheBoatShow
Modepageisdisplayed(5pressesfromtheUser
CalibrationMenuAccesspage).
2.UsetheVMGorTackbuttonstoswitchtheBoat
ShowModeOnandOff(default).
SelectingOnwillputthedisplayintoboatshow
mode.
Note:Boatshowmodeisonlysuitablefor
demonstrationpurposesandshouldNOTbeused
whilstyourvesselisinuse.
Note:Toexitthedealercalibrationpagesatany
timepressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately2
seconds.
Resettingthedisplaytofactorydefaults-i60
FromtheUserCalibrationMenuAccesspage:
1.PresstheDisplaybuttonuntiltheFactoryReset
pageisdisplayed(5pressesfromtheUser
CalibrationMenuAccesspage).
2.Toresetthedisplaytofactorydefaultsettings:
i.UsetheVMGorTackbuttonstochangethe
resetoptiontoF1(default).
ii.PresstheDisplaybuttontoresetyourdisplay
tofactorydefaultsettings.
40i60