4.1Generalcablingguidance
Cabletypesandlength
Itisimportanttousecablesoftheappropriatetypeandlength
Unlessotherwisestateduseonlystandardcablesofthe
correcttype,suppliedbyRaymarine.
Ensurethatanynon-Raymarinecablesareofthecorrect
qualityandgauge.Forexample,longerpowercablerunsmay
requirelargerwiregaugestominimizevoltagedropalongthe
run.
Routingcables
Cablesmustberoutedcorrectly,tomaximizeperformanceand
prolongcablelife.
DoNOTbendcablesexcessively.Whereverpossible,ensure
aminimumbenddiameterof200mm(8in)/minimumbend
radiusof100mm(4in).
100 mm (4 in)
200 mm (8 in)
Protectallcablesfromphysicaldamageandexposuretoheat.
Usetrunkingorconduitwherepossible.DoNOTruncables
throughbilgesordoorways,orclosetomovingorhotobjects.
Securecablesinplaceusingtie-wrapsorlacingtwine.Coil
anyextracableandtieitoutoftheway.
Whereacablepassesthroughanexposedbulkheador
deckhead,useasuitablewatertightfeed-through.
DoNOTruncablesneartoenginesoruorescentlights.
Alwaysroutedatacablesasfarawayaspossiblefrom:
otherequipmentandcables,
highcurrentcarryingacanddcpowerlines,
antennae.
Strainrelief
Ensureadequatestrainreliefisprovided.Protectconnectors
fromstrainandensuretheywillnotpulloutunderextremesea
conditions.
Cableshielding
Ensurethatalldatacablesareproperlyshieldedthatthe
cableshieldingisintact(e.g.hasn’tbeenscrapedoffbybeing
squeezedthroughatightarea).
4.2Connectionsoverview
ConnectionsaremadeusingtheprovidedSeaT alk
ng
and
transducercableconnectorsontherearoftheunit.
SeaTalk
ng
connections
Theunithas2xSeaT alk
ng
connectorsontherearforconnecting
toaSeaT alk
ng
network.
D12 05 6-1
ConnectingSeaTalk
ng
cables
1.Rotatethelockingcollaronthebackoftheunittothe
UNLOCKEDposition.
2.Ensurethespurcableendconnectoriscorrectlyoriented.
3.Fullyinsertthecableconnector.
4.Rotatelockingcollarclockwise(2clicks)untilitsnapsinto
theLOCKEDposition.
Transducerconnections
Transducerconnectionsonlyapplytothei60Windinstrument,
thei60Closehauledwinddoesnotincludetransducer
connectionsasitisarepeaterdisplay.
i60transducerconnections
6
7
3
4
5
D12 39 6-1
1
2
1Blue
Rotor+(Rotavecta)
2Red
Rotor(Rotavecta)
3
GreyWind0V(Shield)
4Yellow
Anemometer(signal)
5
Blue
Cosinewinddirection
6
GreenSinewinddirection
7
RedWindV+
20i60